Serviceline
Serviceline Industrial Sensors
Serviceline Explosion Protection

ターミネーションボード


Narrow down search result list

製品セレクタツールの結果: 236 製品

Manufacturer

Control System Type

Signal Type

Number of Modules


Choose your product


Next PageLast Page
製品

32-channel, 24 V DC supply, Interface for serial or parallel wiring options, Dual RS 485 connections, Slot for HART Multiplexer
System board for Yokogawa CENTUM VP, For 16-channel AO card AAI543, For 16 modules, Recommended module: HiC2031 (AO), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
System board for Yokogawa CENTUM VP, For 16-channel AI card AAI143, For 16 modules, Recommended module: HiD2081 (TI), 24 V DC supply, Hazardous area: spring terminals, blue, Safe area: Yokogawa system connector, 40-pin
Ideal for retrofitting existing installations, Interface for serial or parallel wiring options, 37-pin Sub-D connectors, Redundant power supply connections, HART filter options, Fuse options
32-channel, 24 V DC supply, For analog output cards, HART output filters, Interface for serial or parallel wiring options, 37-pin Sub-D connectors, Slot for HART Multiplexer
System board for Honeywell Safety Manager, For 16-channel DI card SDI-1624, For 8 modules, Recommended module: HiC2822 (DI), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin
System board for Honeywell Universal Safety IO, System board for Honeywell Universal Process IO, For 16-channel cards USIO and UPIO, For 16 modules, Recommended modules: HiC2831R2 (DI), HiC2853R2 (DI), HiC2871 (DO), HiC2025 (AI), HiC2031 (AO), Recommended system cable: CA-HWC300-AIO-DIO-*M, 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: Sub-D connector (male), 37-pin
System board for Honeywell Safety Manager, For 16-channel AI card SAI-1620m, For 16 modules, Recommended module: HiC2025 (AI), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin
System board for Honeywell Safety Manager, For 4 pieces 2-channel card SAO-0220m, For 8 modules, Recommended module: HiC2031 (AO), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin
System board for Honeywell Safety Manager, For 16-channel DI cards SDIL-1608 and SDI-1624, For 16 modules, Recommended modules: HiC2821 (SIL 2), HiC2851 (SIL 3), 24 V DC supply, Hazardous area: pluggable screw terminals, blue, Safe area: SiC plug, 20-pin
Next PageLast Page